HL7 Europe Imaging Study Report, published by HL7 Europe. This guide is not an authorized publication; it is the continuous build for version 0.1.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/oijauregui/ehdsimaging/tree/master and changes regularly. See the Directory of published versions
| Draft as of 2025-03-21 |
Definitions for the EHDSMedia logical model.
Guidance on how to interpret the contents of this table can be foundhere
| 0. EHDSMedia | |
| Definition | C.14 - EHDS refined base model for A photo, video, or audio recording acquired or used in healthcare. Base definition for all types defined in FHIR type system. |
| Short | Media modelBase for all types and resources |
| Control | 0..* |
| Is Modifier | false |
| Logical Model | Instances of this logical model are not marked to be the target of a Reference |
| 2. EHDSMedia.identifier | |
| Definition | Image identifier |
| Short | C.14.1 - Identifier |
| Note | This is a business identifier, not a resource identifier (see discussion) |
| Control | 0..* |
| Type | Identifier |
| 4. EHDSMedia.type | |
| Definition | Classification of media as image, video, audio recording or other media type |
| Short | C.14.2 - Type |
| Control | 0..1 |
| Binding | HL7 MediaType |
| Type | CodeableConcept |
| 6. EHDSMedia.modality | |
| Definition | The type of acquisition equipment/process |
| Short | C.14.3 - Modality |
| Control | 0..1 |
| Binding | HL7 MediaModality |
| Type | CodeableConcept |
| 8. EHDSMedia.view | |
| Definition | The name of the imaging view e.g. Lateral or Antero-posterior |
| Short | C.14.4 - View |
| Control | 0..1 |
| Binding | HL7 MediaCollectionView/Projection |
| Type | CodeableConcept |
| 10. EHDSMedia.subject[x] | |
| Definition | Who/What this Media is a record of |
| Short | C.14.5 - Subject |
| Control | 0..1 |
| Type | Reference(Patient model, Specimen model) |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| 12. EHDSMedia.created[x] | |
| Definition | The date and time(s) at which the media was collected. |
| Short | C.14.6 - Created |
| Control | 0..1 |
| Type | Choice of: dateTime, Period |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 14. EHDSMedia.reason | |
| Definition | Describes why the event occurred in coded or textual form. |
| Short | C.14.7 - Reason |
| Control | 0..* |
| Binding | SNOMED CT |
| Type | CodeableConcept |
| 16. EHDSMedia.bodysite | |
| Definition | Observed body part, i.e. target site |
| Short | C.14.8 - BodySite |
| Control | 0..1 |
| Binding | SNOMED CT |
| Type | CodeableConcept |
| 18. EHDSMedia.deviceName | |
| Definition | The name of the device / manufacturer of the device that was used to make the recording. |
| Short | C.14.9 - Device name |
| Control | 0..1 |
| Type | string |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 20. EHDSMedia.device | |
| Definition | The device used to collect the media. |
| Short | C.14.10 - Device |
| Control | 0..1 |
| Type | Reference(Device model) |
| 22. EHDSMedia.content | |
| Definition | The actual content of the media - inline or by direct reference to the media source file. |
| Short | C.14.11 - Content |
| Control | 1..1 |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSAttachment |
| 24. EHDSMedia.note | |
| Definition | Comments made about the media by the performer, subject or other participants. |
| Short | C.14.12 - Note |
| Control | 0..* |
| Type | Narrative |
| 26. EHDSMedia.performer | |
| Definition | Performer of the imaging acquisition process. |
| Short | C.14.13 - Performer |
| Control | 0..* |
| Type | Reference(Health professional model, Organization model) |
Guidance on how to interpret the contents of this table can be foundhere
| 0. EHDSMedia | |
| Definition | C.14 - EHDS refined base model for A photo, video, or audio recording acquired or used in healthcare. |
| Short | Media model |
| Logical Model | Instances of this logical model are not marked to be the target of a Reference |
| 2. EHDSMedia.identifier | |
| Definition | Image identifier |
| Short | C.14.1 - Identifier |
| Note | This is a business identifier, not a resource identifier (see discussion) |
| Control | 0..* |
| Type | Identifier |
| 4. EHDSMedia.type | |
| Definition | Classification of media as image, video, audio recording or other media type |
| Short | C.14.2 - Type |
| Control | 0..1 |
| Binding | HL7 MediaType |
| Type | CodeableConcept |
| 6. EHDSMedia.modality | |
| Definition | The type of acquisition equipment/process |
| Short | C.14.3 - Modality |
| Control | 0..1 |
| Binding | HL7 MediaModality |
| Type | CodeableConcept |
| 8. EHDSMedia.view | |
| Definition | The name of the imaging view e.g. Lateral or Antero-posterior |
| Short | C.14.4 - View |
| Control | 0..1 |
| Binding | HL7 MediaCollectionView/Projection |
| Type | CodeableConcept |
| 10. EHDSMedia.subject[x] | |
| Definition | Who/What this Media is a record of |
| Short | C.14.5 - Subject |
| Control | 0..1 |
| Type | Reference(Patient model, Specimen model) |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| 12. EHDSMedia.created[x] | |
| Definition | The date and time(s) at which the media was collected. |
| Short | C.14.6 - Created |
| Control | 0..1 |
| Type | Choice of: dateTime, Period |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 14. EHDSMedia.reason | |
| Definition | Describes why the event occurred in coded or textual form. |
| Short | C.14.7 - Reason |
| Control | 0..* |
| Binding | SNOMED CT |
| Type | CodeableConcept |
| 16. EHDSMedia.bodysite | |
| Definition | Observed body part, i.e. target site |
| Short | C.14.8 - BodySite |
| Control | 0..1 |
| Binding | SNOMED CT |
| Type | CodeableConcept |
| 18. EHDSMedia.deviceName | |
| Definition | The name of the device / manufacturer of the device that was used to make the recording. |
| Short | C.14.9 - Device name |
| Control | 0..1 |
| Type | string |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 20. EHDSMedia.device | |
| Definition | The device used to collect the media. |
| Short | C.14.10 - Device |
| Control | 0..1 |
| Type | Reference(Device model) |
| 22. EHDSMedia.content | |
| Definition | The actual content of the media - inline or by direct reference to the media source file. |
| Short | C.14.11 - Content |
| Control | 1..1 |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSAttachment |
| 24. EHDSMedia.note | |
| Definition | Comments made about the media by the performer, subject or other participants. |
| Short | C.14.12 - Note |
| Control | 0..* |
| Type | Narrative |
| 26. EHDSMedia.performer | |
| Definition | Performer of the imaging acquisition process. |
| Short | C.14.13 - Performer |
| Control | 0..* |
| Type | Reference(Health professional model, Organization model) |
Guidance on how to interpret the contents of this table can be foundhere
| 0. EHDSMedia | |
| Definition | C.14 - EHDS refined base model for A photo, video, or audio recording acquired or used in healthcare. |
| Short | Media model |
| Control | 0..* |
| Is Modifier | false |
| Logical Model | Instances of this logical model are not marked to be the target of a Reference |
| 2. EHDSMedia.identifier | |
| Definition | Image identifier |
| Short | C.14.1 - Identifier |
| Note | This is a business identifier, not a resource identifier (see discussion) |
| Control | 0..* |
| Type | Identifier |
| 4. EHDSMedia.type | |
| Definition | Classification of media as image, video, audio recording or other media type |
| Short | C.14.2 - Type |
| Control | 0..1 |
| Binding | HL7 MediaType |
| Type | CodeableConcept |
| 6. EHDSMedia.modality | |
| Definition | The type of acquisition equipment/process |
| Short | C.14.3 - Modality |
| Control | 0..1 |
| Binding | HL7 MediaModality |
| Type | CodeableConcept |
| 8. EHDSMedia.view | |
| Definition | The name of the imaging view e.g. Lateral or Antero-posterior |
| Short | C.14.4 - View |
| Control | 0..1 |
| Binding | HL7 MediaCollectionView/Projection |
| Type | CodeableConcept |
| 10. EHDSMedia.subject[x] | |
| Definition | Who/What this Media is a record of |
| Short | C.14.5 - Subject |
| Control | 0..1 |
| Type | Reference(Patient model, Specimen model) |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| 12. EHDSMedia.created[x] | |
| Definition | The date and time(s) at which the media was collected. |
| Short | C.14.6 - Created |
| Control | 0..1 |
| Type | Choice of: dateTime, Period |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 14. EHDSMedia.reason | |
| Definition | Describes why the event occurred in coded or textual form. |
| Short | C.14.7 - Reason |
| Control | 0..* |
| Binding | SNOMED CT |
| Type | CodeableConcept |
| 16. EHDSMedia.bodysite | |
| Definition | Observed body part, i.e. target site |
| Short | C.14.8 - BodySite |
| Control | 0..1 |
| Binding | SNOMED CT |
| Type | CodeableConcept |
| 18. EHDSMedia.deviceName | |
| Definition | The name of the device / manufacturer of the device that was used to make the recording. |
| Short | C.14.9 - Device name |
| Control | 0..1 |
| Type | string |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 20. EHDSMedia.device | |
| Definition | The device used to collect the media. |
| Short | C.14.10 - Device |
| Control | 0..1 |
| Type | Reference(Device model) |
| 22. EHDSMedia.content | |
| Definition | The actual content of the media - inline or by direct reference to the media source file. |
| Short | C.14.11 - Content |
| Control | 1..1 |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSAttachment |
| 24. EHDSMedia.note | |
| Definition | Comments made about the media by the performer, subject or other participants. |
| Short | C.14.12 - Note |
| Control | 0..* |
| Type | Narrative |
| 26. EHDSMedia.performer | |
| Definition | Performer of the imaging acquisition process. |
| Short | C.14.13 - Performer |
| Control | 0..* |
| Type | Reference(Health professional model, Organization model) |