HL7 Europe Imaging Study Report, published by HL7 Europe. This guide is not an authorized publication; it is the continuous build for version 0.1.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/oijauregui/ehdsimaging/tree/master and changes regularly. See the Directory of published versions
| Draft as of 2025-03-21 |
Definitions for the EHDSLaboratoryObservation logical model.
Guidance on how to interpret the contents of this table can be foundhere
| 0. EHDSLaboratoryObservation | |
| Definition | C.11 - EHDS refined base model for Observation performed by laboratory Base definition for all types defined in FHIR type system. |
| Short | Laboratory observation modelBase for all types and resources |
| Control | 0..* |
| Is Modifier | false |
| Logical Model | Instances of this logical model are not marked to be the target of a Reference |
| 2. EHDSLaboratoryObservation.observationDate[x] | |
| Definition | Clinically relevant time or time period for the observation. |
| Short | C.10.1 - Observation date |
| Control | 1..1 |
| Type | Choice of: dateTime, Period |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 4. EHDSLaboratoryObservation.observationCode | |
| Definition | Code representing the observation using the agreed code systems. |
| Short | C.10.2 - Observation code |
| Control | 1..1 |
| Binding | LOINC, NPU |
| Type | CodeableConcept |
| 6. EHDSLaboratoryObservation.observationName | |
| Definition | Full name of the observation according to the used test coding standard. |
| Short | C.10.3 - Observation name |
| Control | 1..1 |
| Type | string |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 8. EHDSLaboratoryObservation.observationOriginalName | |
| Definition | Original (conventional) name of the observation |
| Short | C.10.4 - Observation original name |
| Control | 0..1 |
| Type | string |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 10. EHDSLaboratoryObservation.observationMethod | |
| Definition | Observation method (measurement principle) to obtain the result. |
| Short | C.10.5 - Observation method |
| Control | 0..1 |
| Binding | SNOMED CT |
| Type | CodeableConcept |
| 12. EHDSLaboratoryObservation.observationDevice | |
| Definition | Device (e.g. analyser) that generates the measurements |
| Short | C.10.6 - Observation device |
| Control | 0..1 |
| Binding | SNOMED CT, EMDN |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSDevice |
| 14. EHDSLaboratoryObservation.order | |
| Definition | Identifies order and order placer this observation belongs to. |
| Short | C.10.7 - Order |
| Control | 0..1 |
| Type | Reference(Service request model) |
| 16. EHDSLaboratoryObservation.performer | |
| Definition | Identifies the originator/author and provides provenance information about the source of the results data that may have not originated with the source of the whole Laboratory Report document. |
| Short | C.10.8 - Performer |
| Control | 0..1 |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSHealthProfessional |
| 18. EHDSLaboratoryObservation.reporter | |
| Definition | With certain observation results, e.g. there may also be an interpreter or a person responsible for validation. |
| Short | C.10.9 - Reporter |
| Control | 0..1 |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSHealthProfessional |
| 20. EHDSLaboratoryObservation.observationResult | |
| Definition | Result of the observation including text, numeric and coded results of the measurement and measurement uncertainty. Content of the observation result will vary according to the type of the observation. |
| Short | C.10.10 - Observation result |
| Control | 1..1 |
| Binding | SNOMED CT (for ordinal or nominal scale results and result interpretation), UCUM (for units) |
| Type | Base |
| 22. EHDSLaboratoryObservation.observationResult.textualResult | |
| Definition | Narrative text result |
| Short | C.10.10.1 - Textual Result |
| Control | 0..1 |
| Type | string |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 24. EHDSLaboratoryObservation.observationResult.numericResult | |
| Definition | A numeric value or interval (open or closed) of the result, result units of the measurement should be provided Measurement uncertainty interval are provided if needed. |
| Short | C.10.10.2 - Numeric Result |
| Control | 0..1 |
| Type | Base |
| 26. EHDSLaboratoryObservation.observationResult.numericResult.numericValue[x] | |
| Definition | A numeric value or interval (open or closed) of the result |
| Short | C.10.10.2.1 - Numeric value |
| Control | 0..1 |
| Type | Choice of: Quantity, Range |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| 28. EHDSLaboratoryObservation.observationResult.numericResult.units | |
| Definition | Result units of the measurement |
| Short | C.10.10.2.2 - Units |
| Control | 0..1 |
| Binding | UCUM |
| Type | CodeableConcept |
| 30. EHDSLaboratoryObservation.observationResult.numericResult.uncertainty | |
| Definition | Measurement uncertainty type and interval should be provided if needed. |
| Short | C.10.10.2.3 - Uncertainty |
| Control | 0..1 |
| Type | Base |
| 32. EHDSLaboratoryObservation.observationResult.codedResult | |
| Definition | A coded result from a selected coding system(s). This could be a code describing bacteria or other microorganism identified, description of urinary concernment, code explaining technical reason why the test could not be done etc. |
| Short | C.10.10.3 - Coded Result |
| Control | 0..1 |
| Binding | SNOMED CT |
| Type | CodeableConcept |
| 34. EHDSLaboratoryObservation.dataAbsentReason | |
| Definition | Provides a reason why the expected value in the element Observation.value[x] is missing. |
| Short | C.10.11 - dataAbsentReason |
| Control | 0..1 |
| Binding | HL7 Data absent reason |
| Type | CodeableConcept |
| 36. EHDSLaboratoryObservation.referenceRange | |
| Definition | Reference range, multiple reference ranges of different types culd by providedProvides guide for interpretation of result. Reference ranges are usually implied only for a numeric scale type. Use of the same units for reference range and value is implied. |
| Short | C.10.12 - Reference range |
| Control | 0..* |
| Type | Base |
| 38. EHDSLaboratoryObservation.observationInterpretation | |
| Definition | Information about reference intervals and result interpretation. |
| Short | C.10.13 - Observation interpretation |
| Control | 0..* |
| Binding | SNOMED CT, HL7 ObservationInterpretation |
| Type | CodeableConcept |
| 40. EHDSLaboratoryObservation.triggeredBy[x] | |
| Definition | Identifies the observation(s) that triggered the performance of this observation. |
| Short | C.10.14 - Triggered by |
| Control | 0..* |
| Type | Choice of: https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSLaboratoryObservation, https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSObservation |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| 42. EHDSLaboratoryObservation.hasMember[x] | |
| Definition | This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group. |
| Short | C.10.15 - Has member |
| Control | 0..* |
| Type | Choice of: https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSLaboratoryObservation, https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSObservation |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| 44. EHDSLaboratoryObservation.resultDescription | |
| Definition | Comments and narrative representation of the observation result and findings. |
| Short | C.10.16 - Result description |
| Control | 0..1 |
| Type | string |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 46. EHDSLaboratoryObservation.anatomicLocation | |
| Definition | Anatomic location and laterality where the observation should be or was performed. |
| Short | C.10.17 - Anatomic location |
| Control | 0..1 |
| Binding | SNOMED CT |
| Type | CodeableConcept |
| 48. EHDSLaboratoryObservation.subject | |
| Definition | The patient, or group of patients, location, device, organization, procedure or practitioner this observation is about. |
| Short | C.10.18 - Subject |
| Control | 1..1 |
| Type | Reference(Patient model, Location model, Device model, Organization model, Health professional model, Procedure model) |
| 50. EHDSLaboratoryObservation.component | |
| Definition | Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. |
| Short | C.10.19 - Component |
| Control | 0..* |
| Type | Base |
| 52. EHDSLaboratoryObservation.component.code | |
| Definition | Code representing the observation using the agreed code systems. |
| Short | C.10.19.1 - Code |
| Control | 1..1 |
| Binding | LOINC, NPU, SNOMED CT |
| Type | CodeableConcept |
| 54. EHDSLaboratoryObservation.component.textualResult | |
| Definition | Narrative text result |
| Short | C.10.19.2 - Textual Result |
| Control | 0..1 |
| Type | string |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 56. EHDSLaboratoryObservation.component.numericResult | |
| Definition | A numeric value or interval (open or closed) of the result, result units of the measurement should be provided Measurement uncertainty interval are provided if needed. |
| Short | C.10.19.3 - Numeric Result |
| Control | 0..1 |
| Type | Base |
| 58. EHDSLaboratoryObservation.component.numericResult.numericValue[x] | |
| Definition | A numeric value or interval (open or closed) of the result |
| Short | C.10.19.3.1 - Numeric value |
| Control | 0..1 |
| Type | Choice of: Quantity, Range |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| 60. EHDSLaboratoryObservation.component.numericResult.units | |
| Definition | Result units of the measurement |
| Short | C.10.19.3.2 - Units |
| Control | 0..1 |
| Binding | UCUM |
| Type | CodeableConcept |
| 62. EHDSLaboratoryObservation.component.numericResult.uncertainty | |
| Definition | Measurement uncertainty type and interval should be provided if needed. |
| Short | C.10.19.3.3 - Uncertainty |
| Control | 0..1 |
| Type | Base |
| 64. EHDSLaboratoryObservation.component.codedResult | |
| Definition | A coded result from a selected coding system(s). This could be a code describing bacteria or other microorganism identified, description of urinary concernment, code explaining technical reason why the test could not be done etc. |
| Short | C.10.19.4 - Coded Result |
| Control | 0..1 |
| Binding | SNOMED CT |
| Type | CodeableConcept |
| 66. EHDSLaboratoryObservation.component.dataAbsentReason | |
| Definition | Provides a reason why the expected value in the element Observation.value[x] is missing. |
| Short | C.10.19.5 - dataAbsentReason |
| Control | 0..1 |
| Binding | HL7 Data absent reason |
| Type | CodeableConcept |
| 68. EHDSLaboratoryObservation.component.referenceRange | |
| Definition | Reference range, multiple reference ranges of different types culd by providedProvides guide for interpretation of result. Reference ranges are usually implied only for a numeric scale type. Use of the same units for reference range and value is implied. |
| Short | C.10.19.6 - Reference range |
| Control | 0..* |
| Type | Base |
| 70. EHDSLaboratoryObservation.component.observationInterpretation | |
| Definition | Information about reference intervals and result interpretation. |
| Short | C.10.19.7 - Observation interpretation |
| Control | 0..* |
| Binding | SNOMED CT, HL7 ObservationInterpretation |
| Type | CodeableConcept |
| 72. EHDSLaboratoryObservation.status | |
| Definition | The status of the result value. |
| Short | C.10.19.8 - Status |
| Control | 1..1 |
| Binding | HL7 Observation status |
| Type | CodeableConcept |
| 74. EHDSLaboratoryObservation.testKit | |
| Definition | Laboratory test kit used during measurement. |
| Short | C.11.2 - Test kit |
| Control | 0..1 |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSDevice |
| 76. EHDSLaboratoryObservation.calibrator | |
| Definition | Information about which end-user calibrator the laboratory used for the measurement to indicate the metrological traceability chain. |
| Short | C.11.3 - Calibrator |
| Control | 0..1 |
| Type | Identifier |
| 78. EHDSLaboratoryObservation.accreditationStatus | |
| Definition | Accreditation status of the laboratory for the particular observation. |
| Short | C.11.4 - Accreditation status |
| Control | 0..1 |
| Binding | Code system to be specified |
| Type | CodeableConcept |
| 80. EHDSLaboratoryObservation.previousResults | |
| Definition | Previous results of the same observation |
| Short | C.11.5 - Previous results |
| Control | 0..* |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSLaboratoryObservation |
Guidance on how to interpret the contents of this table can be foundhere
| 0. EHDSLaboratoryObservation | |
| Definition | C.11 - EHDS refined base model for Observation performed by laboratory |
| Short | Laboratory observation model |
| Logical Model | Instances of this logical model are not marked to be the target of a Reference |
| 2. EHDSLaboratoryObservation.observationCode | |
| Binding | LOINC, NPU |
| 4. EHDSLaboratoryObservation.testKit | |
| Definition | Laboratory test kit used during measurement. |
| Short | C.11.2 - Test kit |
| Control | 0..1 |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSDevice |
| 6. EHDSLaboratoryObservation.calibrator | |
| Definition | Information about which end-user calibrator the laboratory used for the measurement to indicate the metrological traceability chain. |
| Short | C.11.3 - Calibrator |
| Control | 0..1 |
| Type | Identifier |
| 8. EHDSLaboratoryObservation.accreditationStatus | |
| Definition | Accreditation status of the laboratory for the particular observation. |
| Short | C.11.4 - Accreditation status |
| Control | 0..1 |
| Binding | Code system to be specified |
| Type | CodeableConcept |
| 10. EHDSLaboratoryObservation.previousResults | |
| Definition | Previous results of the same observation |
| Short | C.11.5 - Previous results |
| Control | 0..* |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSLaboratoryObservation |
Guidance on how to interpret the contents of this table can be foundhere
| 0. EHDSLaboratoryObservation | |
| Definition | C.11 - EHDS refined base model for Observation performed by laboratory |
| Short | Laboratory observation model |
| Control | 0..* |
| Is Modifier | false |
| Logical Model | Instances of this logical model are not marked to be the target of a Reference |
| 2. EHDSLaboratoryObservation.observationDate[x] | |
| Definition | Clinically relevant time or time period for the observation. |
| Short | C.10.1 - Observation date |
| Control | 1..1 |
| Type | Choice of: dateTime, Period |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 4. EHDSLaboratoryObservation.observationCode | |
| Definition | Code representing the observation using the agreed code systems. |
| Short | C.10.2 - Observation code |
| Control | 1..1 |
| Binding | LOINC, NPU |
| Type | CodeableConcept |
| 6. EHDSLaboratoryObservation.observationName | |
| Definition | Full name of the observation according to the used test coding standard. |
| Short | C.10.3 - Observation name |
| Control | 1..1 |
| Type | string |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 8. EHDSLaboratoryObservation.observationOriginalName | |
| Definition | Original (conventional) name of the observation |
| Short | C.10.4 - Observation original name |
| Control | 0..1 |
| Type | string |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 10. EHDSLaboratoryObservation.observationMethod | |
| Definition | Observation method (measurement principle) to obtain the result. |
| Short | C.10.5 - Observation method |
| Control | 0..1 |
| Binding | SNOMED CT |
| Type | CodeableConcept |
| 12. EHDSLaboratoryObservation.observationDevice | |
| Definition | Device (e.g. analyser) that generates the measurements |
| Short | C.10.6 - Observation device |
| Control | 0..1 |
| Binding | SNOMED CT, EMDN |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSDevice |
| 14. EHDSLaboratoryObservation.order | |
| Definition | Identifies order and order placer this observation belongs to. |
| Short | C.10.7 - Order |
| Control | 0..1 |
| Type | Reference(Service request model) |
| 16. EHDSLaboratoryObservation.performer | |
| Definition | Identifies the originator/author and provides provenance information about the source of the results data that may have not originated with the source of the whole Laboratory Report document. |
| Short | C.10.8 - Performer |
| Control | 0..1 |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSHealthProfessional |
| 18. EHDSLaboratoryObservation.reporter | |
| Definition | With certain observation results, e.g. there may also be an interpreter or a person responsible for validation. |
| Short | C.10.9 - Reporter |
| Control | 0..1 |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSHealthProfessional |
| 20. EHDSLaboratoryObservation.observationResult | |
| Definition | Result of the observation including text, numeric and coded results of the measurement and measurement uncertainty. Content of the observation result will vary according to the type of the observation. |
| Short | C.10.10 - Observation result |
| Control | 1..1 |
| Binding | SNOMED CT (for ordinal or nominal scale results and result interpretation), UCUM (for units) |
| Type | Base |
| 22. EHDSLaboratoryObservation.observationResult.textualResult | |
| Definition | Narrative text result |
| Short | C.10.10.1 - Textual Result |
| Control | 0..1 |
| Type | string |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 24. EHDSLaboratoryObservation.observationResult.numericResult | |
| Definition | A numeric value or interval (open or closed) of the result, result units of the measurement should be provided Measurement uncertainty interval are provided if needed. |
| Short | C.10.10.2 - Numeric Result |
| Control | 0..1 |
| Type | Base |
| 26. EHDSLaboratoryObservation.observationResult.numericResult.numericValue[x] | |
| Definition | A numeric value or interval (open or closed) of the result |
| Short | C.10.10.2.1 - Numeric value |
| Control | 0..1 |
| Type | Choice of: Quantity, Range |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| 28. EHDSLaboratoryObservation.observationResult.numericResult.units | |
| Definition | Result units of the measurement |
| Short | C.10.10.2.2 - Units |
| Control | 0..1 |
| Binding | UCUM |
| Type | CodeableConcept |
| 30. EHDSLaboratoryObservation.observationResult.numericResult.uncertainty | |
| Definition | Measurement uncertainty type and interval should be provided if needed. |
| Short | C.10.10.2.3 - Uncertainty |
| Control | 0..1 |
| Type | Base |
| 32. EHDSLaboratoryObservation.observationResult.codedResult | |
| Definition | A coded result from a selected coding system(s). This could be a code describing bacteria or other microorganism identified, description of urinary concernment, code explaining technical reason why the test could not be done etc. |
| Short | C.10.10.3 - Coded Result |
| Control | 0..1 |
| Binding | SNOMED CT |
| Type | CodeableConcept |
| 34. EHDSLaboratoryObservation.dataAbsentReason | |
| Definition | Provides a reason why the expected value in the element Observation.value[x] is missing. |
| Short | C.10.11 - dataAbsentReason |
| Control | 0..1 |
| Binding | HL7 Data absent reason |
| Type | CodeableConcept |
| 36. EHDSLaboratoryObservation.referenceRange | |
| Definition | Reference range, multiple reference ranges of different types culd by providedProvides guide for interpretation of result. Reference ranges are usually implied only for a numeric scale type. Use of the same units for reference range and value is implied. |
| Short | C.10.12 - Reference range |
| Control | 0..* |
| Type | Base |
| 38. EHDSLaboratoryObservation.observationInterpretation | |
| Definition | Information about reference intervals and result interpretation. |
| Short | C.10.13 - Observation interpretation |
| Control | 0..* |
| Binding | SNOMED CT, HL7 ObservationInterpretation |
| Type | CodeableConcept |
| 40. EHDSLaboratoryObservation.triggeredBy[x] | |
| Definition | Identifies the observation(s) that triggered the performance of this observation. |
| Short | C.10.14 - Triggered by |
| Control | 0..* |
| Type | Choice of: https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSLaboratoryObservation, https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSObservation |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| 42. EHDSLaboratoryObservation.hasMember[x] | |
| Definition | This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group. |
| Short | C.10.15 - Has member |
| Control | 0..* |
| Type | Choice of: https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSLaboratoryObservation, https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSObservation |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| 44. EHDSLaboratoryObservation.resultDescription | |
| Definition | Comments and narrative representation of the observation result and findings. |
| Short | C.10.16 - Result description |
| Control | 0..1 |
| Type | string |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 46. EHDSLaboratoryObservation.anatomicLocation | |
| Definition | Anatomic location and laterality where the observation should be or was performed. |
| Short | C.10.17 - Anatomic location |
| Control | 0..1 |
| Binding | SNOMED CT |
| Type | CodeableConcept |
| 48. EHDSLaboratoryObservation.subject | |
| Definition | The patient, or group of patients, location, device, organization, procedure or practitioner this observation is about. |
| Short | C.10.18 - Subject |
| Control | 1..1 |
| Type | Reference(Patient model, Location model, Device model, Organization model, Health professional model, Procedure model) |
| 50. EHDSLaboratoryObservation.component | |
| Definition | Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. |
| Short | C.10.19 - Component |
| Control | 0..* |
| Type | Base |
| 52. EHDSLaboratoryObservation.component.code | |
| Definition | Code representing the observation using the agreed code systems. |
| Short | C.10.19.1 - Code |
| Control | 1..1 |
| Binding | LOINC, NPU, SNOMED CT |
| Type | CodeableConcept |
| 54. EHDSLaboratoryObservation.component.textualResult | |
| Definition | Narrative text result |
| Short | C.10.19.2 - Textual Result |
| Control | 0..1 |
| Type | string |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 56. EHDSLaboratoryObservation.component.numericResult | |
| Definition | A numeric value or interval (open or closed) of the result, result units of the measurement should be provided Measurement uncertainty interval are provided if needed. |
| Short | C.10.19.3 - Numeric Result |
| Control | 0..1 |
| Type | Base |
| 58. EHDSLaboratoryObservation.component.numericResult.numericValue[x] | |
| Definition | A numeric value or interval (open or closed) of the result |
| Short | C.10.19.3.1 - Numeric value |
| Control | 0..1 |
| Type | Choice of: Quantity, Range |
| [x] Note | SeeChoice of Data Typesfor further information about how to use [x] |
| 60. EHDSLaboratoryObservation.component.numericResult.units | |
| Definition | Result units of the measurement |
| Short | C.10.19.3.2 - Units |
| Control | 0..1 |
| Binding | UCUM |
| Type | CodeableConcept |
| 62. EHDSLaboratoryObservation.component.numericResult.uncertainty | |
| Definition | Measurement uncertainty type and interval should be provided if needed. |
| Short | C.10.19.3.3 - Uncertainty |
| Control | 0..1 |
| Type | Base |
| 64. EHDSLaboratoryObservation.component.codedResult | |
| Definition | A coded result from a selected coding system(s). This could be a code describing bacteria or other microorganism identified, description of urinary concernment, code explaining technical reason why the test could not be done etc. |
| Short | C.10.19.4 - Coded Result |
| Control | 0..1 |
| Binding | SNOMED CT |
| Type | CodeableConcept |
| 66. EHDSLaboratoryObservation.component.dataAbsentReason | |
| Definition | Provides a reason why the expected value in the element Observation.value[x] is missing. |
| Short | C.10.19.5 - dataAbsentReason |
| Control | 0..1 |
| Binding | HL7 Data absent reason |
| Type | CodeableConcept |
| 68. EHDSLaboratoryObservation.component.referenceRange | |
| Definition | Reference range, multiple reference ranges of different types culd by providedProvides guide for interpretation of result. Reference ranges are usually implied only for a numeric scale type. Use of the same units for reference range and value is implied. |
| Short | C.10.19.6 - Reference range |
| Control | 0..* |
| Type | Base |
| 70. EHDSLaboratoryObservation.component.observationInterpretation | |
| Definition | Information about reference intervals and result interpretation. |
| Short | C.10.19.7 - Observation interpretation |
| Control | 0..* |
| Binding | SNOMED CT, HL7 ObservationInterpretation |
| Type | CodeableConcept |
| 72. EHDSLaboratoryObservation.status | |
| Definition | The status of the result value. |
| Short | C.10.19.8 - Status |
| Control | 1..1 |
| Binding | HL7 Observation status |
| Type | CodeableConcept |
| 74. EHDSLaboratoryObservation.testKit | |
| Definition | Laboratory test kit used during measurement. |
| Short | C.11.2 - Test kit |
| Control | 0..1 |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSDevice |
| 76. EHDSLaboratoryObservation.calibrator | |
| Definition | Information about which end-user calibrator the laboratory used for the measurement to indicate the metrological traceability chain. |
| Short | C.11.3 - Calibrator |
| Control | 0..1 |
| Type | Identifier |
| 78. EHDSLaboratoryObservation.accreditationStatus | |
| Definition | Accreditation status of the laboratory for the particular observation. |
| Short | C.11.4 - Accreditation status |
| Control | 0..1 |
| Binding | Code system to be specified |
| Type | CodeableConcept |
| 80. EHDSLaboratoryObservation.previousResults | |
| Definition | Previous results of the same observation |
| Short | C.11.5 - Previous results |
| Control | 0..* |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSLaboratoryObservation |